MPO / MTP Trunk Cables

Optic Fiber Patch Cord

MPO / MTP Trunk Cables

Oyi MTP/MPO Trunk & Fan-out trunk patch cords provide an efficient way to install a large number of cables quickly. It also provides high flexibility on unplugging and re-use. It is especially suitable for the areas that require rapid deployment of high-density backbone cabling in data centers, and high fibre environments for high performance.

 

MPO / MTP branch fan-out cable of us use high-density multi-core fiber cables and MPO / MTP connector

through the intermediate branch structure to realize switching branch from the MPO / MTP to LC, SC, FC, ST, MTRJ and other common connectors. A variety of 4-144 single-mode and multi-mode optical cables can be used, such as common G652D/G657A1/G657A2 single-mode fiber, multimode 62.5/125, 10G OM2/OM3/OM4, or 10G multimode optical cable with high bending performance and so on .It is suitable for direct connection of MTP-LC branch cables–one end is 40Gbps QSFP+, and the other end is four 10Gbps SFP+. This connection decomposes one 40G into four 10G. In many existing DC environments, LC-MTP cables are used to support high-density backbone fibers between switches, rack-mounted panels, and main distribution wiring boards.


Product Detail

FAQ

Product Tags

The Advantage

High-qualified process and test guarantee

High-density applications to save wiring space

Optimum optical network performance

Optimal data center cabling solution application

Product Features

1.Easy to deploy - Factory-terminated systems can save installation and network reconfiguration time.

2.Reliability - use high-standard components to ensure product quality.

3.Factory terminated and tested

4.Allow easy migration from 10GbE to 40GbE or 100GbE

5.Ideal for 400G High-Speed Network connection

6. Excellent repeatability, exchangeability, wearability and stability.

7.Constructed from high quality connectors and standard fibers.

8. Applicable connector: FC, SC, ST, LC and etc.

9. Cable material: PVC, LSZH, OFNR, OFNP.

10. Single-mode or multi-mode available, OS1, OM1, OM2, OM3, OM4 or OM5.

11. Environmentally stable.

Applications

Telecommunication system.

2. Optical communication networks.

3. CATV, FTTH, LAN.

4. Data processing network.

5. Optical transmission system.

6. Test equipment.

NOTE: We can provide specify patch cord which required by customer.

Specifications

MPO/MTP Connectors:

Type

Single-mode (APC polish)

Single-mode (PC polish)

Multi-mode (PC polish)

Fiber Count

4,8,12,24,48,72,96,144

Fiber Type

G652D,G657A1,etc

G652D,G657A1,etc

OM1,OM2,OM3,OM4,etc

Maximum Insertion Loss (dB)

Elit/Low Loss

Standard

Elit/Low Loss

Standard

Elit/Low Loss

Standard

≤0.35dB

0.25dB Typical

≤0.7dB

0.5dB Typical

≤0.35dB

0.25dB Typical

≤0.7dB

0.5dBTypical

≤0.35dB

0.2dB Typical

≤0.5dB

0.35dB Typical

Operating Wavelength (nm)

1310/1550

1310/1550

850/1300

Return Loss (dB)

≥60

≥50

≥30

Durability

≥200 times

Operating Temperature (C)

-45~+75

Storage Temperature (C)

-45~+85

Conmector

MTP,MPO

Conmector Type

MTP-Male,Female;MPO-Male,Female

Polarity

Type A,Type B,Type C

LC/SC/FC Connectors:

Type

Single-mode (APC polish)

Single-mode (PC polish)

Multi-mode (PC polish)

Fiber Count

4,8,12,24,48,72,96,144

Fiber Type

G652D,G657A1,etc

G652D,G657A1,etc

OM1,OM2,OM3,OM4,etc

Maximum Insertion Loss (dB)

Low Loss

Standard

Low Loss

Standard

Low Loss

Standard

≤0.1dB

0.05dB Typical

≤0.3dB

0.25dB Typical

≤0.1dB

0.05dB Typical

≤0.3dB

0.25dB Typical

≤0.1dB

0.05dB Typical

≤0.3dB

0.25dB Typical

Operating Wavelength (nm)

1310/1550

1310/1550

850/1300

Return Loss (dB)

≥60

≥50

≥30

Durability

≥500 times

Operating Temperature (C)

-45~+75

Storage Temperature (C)

-45~+85

Remarks : All MPO/MTP patch cords have 3 kinds of polarity.It are Type A i.e.straight trough type (1-to-1, ..12-to-12.),and Type B i.e.Cross type (1-to-12, ...12-to-1),and Type C i.e.Cross Pair type ( 1 to 2,...12 to 11)

Packaging Information

LC -MPO 8F 3M as a reference.

1.1 pc in 1 plastic bag.
2.500 pcs in carton box.
3.Outer carton box size: 46*46*28.5cm, weight: 19kg.
4.OEM service available for mass quantity, can print logo on cartons.

Optic Fiber Patch Cord

Inner Packaging

b
c

Outer Carton

d
e
  • Products Recommended

    • GJYFKH

      GJYFKH

    • OYI-DIN-00 Series

      OYI-DIN-00 Series

      DIN-00 is a DIN rail mounted fiber optic terminal box that used for fiber connection and distribution. It is made of aluminum, inside with plastic splice tray, light weight, good to use.

    • Loose Tube Non-metallic Heavy Type Rodent Protected Cable

      Loose Tube Non-metallic Heavy Type Rodent Prote...

      Insert the optical fiber into the PBT loose tube, fill the loose tube with waterproof ointment. The center of the cable core is a non-metallic reinforced core, and the gap is filled with waterproof ointment. The loose tube (and filler) is twisted around the center to strengthen the core, forming a compact and circular cable core. A layer of protective material is extruded outside the cable core, and glass yarn is placed outside the protective tube as a rodent proof material. Then, a layer of polyethylene (PE) protective material is extruded.(WITH DOUBLE SHEATHS)

    • OYI-FOSC-D106H

      OYI-FOSC-D106H

      The OYI-FOSC-H6 dome fiber optic splice closure is used in aerial, wall-mounting, and underground applications for the straight-through and branching splice of the fiber cable. Dome splicing closures are excellent protection of fiber optic joints from outdoor environments such as UV, water, and weather, with leak-proof sealing and IP68 protection.

    • Self-supporting  Figure 8  Fiber Optic Cable

      Self-supporting Figure 8 Fiber Optic Cable

      The 250um fibers are positioned in a loose tube made of high modulus plastic. The tubes are filled with a water-resistant filling compound. A steel wire is located in the center of the core as a metallic strength member. The tubes (and fibers) are stranded around the strength member into a compact and circular cable core. After an Aluminum (or steel tape) Polyethylene Laminate (APL) moisture barrier is applied around the cable core, this part of the cable, accompanied by the stranded wires as the supporting part, is completed with a polyethylene (PE) sheath to form a figure 8 structure. Figure 8 cables, GYTC8A and GYTC8S, are also available upon request. This type of cable is specifically designed for self-supporting aerial installation.

    • Armoured Patchcord

      Armoured Patchcord

      Oyi armoured patch cord provides flexible interconnection to active equipment, passive optical devices and cross connects. These patch cords are manufactured so as to withstand side pressure and repeated bending and are used in external applications in customer premises, central offices and in harsh environment. Armoured patch cords are constructed with a stainless steel tube over a standard patch cord with an outer jacket. The flexible metal tube limits the bending radius, preventing the optical fibre from breaking. This ensures a safe and durable optical fibre network system.

      According to the transmission medium, it divides to Single Mode and Multi Mode Fiber Optic Pigtail; According to the connector structure type, it divides FC, SC, ST, MU, MTRJ, D4, E2000, LC etc.; According to the polished ceramic end-face, it divides to PC, UPC and APC.

      Oyi can provide all kinds of optic fiber patchcord products; The transmission mode, optical cable type and connector type can be arbitrarily matched. It has the advantages of stable transmission, high reliability and customization; it is widely used in optical network scenarios such as central office, FTTX and LAN etc.

    If you're looking for a reliable, high-speed fibre optic cable solution, look no further than OYI. Contact us now to see how we can help you stay connected and take your business to the next level.

    Facebook

    YouTube

    YouTube

    Instagram

    Instagram

    LinkedIn

    LinkedIn

    Whatsapp

    +8618926041961

    Email

    sales@oyii.net