LGX Insert Cassette Type Splitter

Optic Fiber PLC Splitter

LGX Insert Cassette Type Splitter

Fiber optic PLC splitter, also known as a beam splitter, is an integrated waveguide optical power distribution device based on a quartz substrate. It is similar to a coaxial cable transmission system. The optical network system also requires an optical signal to be coupled to the branch distribution. The fiber optic splitter is one of the most important passive devices in the optical fiber link. It is an optical fiber tandem device with many input terminals and many output terminals. It is especially applicable to a passive optical network (EPON, GPON, BPON, FTTX, FTTH, etc.) to connect the ODF and the terminal equipment and to achieve the branching of the optical signal.


Product Detail

FAQ

Product Tags

OYI provide a highly precise LGX insert cassette-type PLC splitter for the construction of optical networks. With low requirements for placement position and environment, its compact cassette-type design can easily be placed into an optical fiber distribution box, optical fiber junction box, or any kind of box that can reserve some space. It can be easily applied in FTTx construction, optical network construction, CATV networks, and more.

The LGX insert cassette-type PLC splitter family includes 1x2, 1x4, 1x8, 1x16, 1x32, 1x64, 2x2, 2x4, 2x8, 2x16, 2x32, 2x64, which are tailored to different applications and markets. They have a compact size with wide bandwidth. All products meet ROHS, GR-1209-CORE-2001, and GR-1221-CORE-1999 standards.

Product Features

Wide operating wavelength: from 1260nm to 1650nm.

Low insertion loss.

Low polarization related loss.

Miniaturized design.

Good consistency between channels.

High reliability and stability.

Passed GR-1221-CORE reliability test.

Compliance with RoHS standards.

Different types of connectors can be provided according to customer needs, with fast installation and reliable performance.

Technical Parameters

Working Temperature: -40℃~80℃

FTTX (FTTP, FTTH, FTTN, FTTC).

FTTX networks.

Data Communication.

PON networks.

Fiber Type: G657A1, G657A2, G652D.

Test required: The RL of UPC is 50dB, APC is 55dB; UPC Connectors: IL add 0.2 dB, APC Connectors: IL add 0.3 dB.

Wide operating wavelength: from 1260nm to 1650nm.

Specifications

1×N (N>2) PLC (With connector) Optical parameters
Parameters 1×2 1×4 1×8 1×16 1×32 1×64
Operation Wavelength (nm) 1260-1650
Insertion Loss (dB) Max 4.2 7.4 10.7 13.8 17.4 21.2
Return Loss (dB) Min 55 55 55 55 55 55
50 50 50 50 50 50
PDL (dB) Max 0.2 0.3 0.3 0.3 0.3 0.5
Directivity (dB) Min 55 55 55 55 55 55
WDL (dB) 0.4 0.4 0.4 0.5 0.5 0.5
Pigtail Length (m) 1.2 (±0.1) or customer specified
Fiber Type SMF-28e with 0.9mm tight buffered fiber
Operation Temperature (℃) -40~85
Storage Temperature (℃) -40~85
Module Dimension (L×W×H) (mm) 130×100x25 130×100x25 130×100x25 130×100x50 130×100×102 130×100×206
2×N (N>2) PLC (With connector) Optical parameters
Parameters

2×4

2×8

2×16

2×32

Operation Wavelength (nm)

1260-1650

Insertion Loss (dB) Max

7.7

11.4

14.8

17.7

Return Loss (dB) Min

55

55

55

55

 

50

50

50

50

PDL (dB) Max

0.2

0.3

0.3

0.3

Directivity (dB) Min

55

55

55

55

WDL (dB)

0.4

0.4

0.5

0.5

Pigtail Length (m)

1.2 (±0.1) or customer specified

Fiber Type

SMF-28e with 0.9mm tight buffered fiber

Operation Temperature (℃)

 -40~85

Storage Temperature (℃)

 -40~85

Module Dimension (L×W×H) (mm)

130×100x25

130×100x25

130×100x50

130×100x102

Remark: The RL of UPC is 50dB, the RL of APC is 55dB.

Product Pictures

1*4 LGX PLC Splitter

1*4 LGX PLC Splitter

LGX PLC Splitter

1*8 LGX PLC Splitter

LGX PLC Splitter

1*16 LGX PLC Splitter

Packaging Information

1x16-SC/APC as a reference. 

1 pc in 1 plastic box.

50 specific PLC splitter in carton box.

Outer carton box size: 55*45*45 cm, weight: 10kg.

OEM service available for mass quantity, can print logo on cartons.

LGX-Insert-Cassette-Type-Splitter-1

Inner Packaging

Outer Carton

Outer Carton

Packaging Information
  • Products Recommended

    • OYI-F504

      OYI-F504

      Optical Distribution Rack is an enclosed frame used to provide cable interconnection between communication facilities, it organizes IT equipment in to standardized assemblies that makes efficient use of space and other resources. The Optical Distribution Rack is specifically designed to provide bend radius protection, better fiber distribution and cable management.

    • OYI-FOSC-D103H

      OYI-FOSC-D103H

      The OYI-FOSC-D103H dome fiber optic splice closure is used in aerial, wall-mounting, and underground applications for the straight-through and branching splice of the fiber cable. Dome splicing closures are excellent protection of fiber optic joints from outdoor environments such as UV, water, and weather, with leak-proof sealing and IP68 protection.
      The closure has 5 entrance ports on the end (4 round ports and 1 oval port). The shell of the product is made from ABS/PC+ABS material. The shell and the base are sealed by pressing the silicone rubber with the allocated clamp. The entry ports are sealed by heat-shrinkable tubes. The closures can be opened again after being sealed and reused without changing the sealing material.
      The closure’s main construction includes the box, splicing, and it can be configured with adapters and optical splitters.

    • Female Attenuator

      Female Attenuator

      OYI FC male-female attenuator plug type fixed attenuator family offers high performance of various fixed attenuation for industrial standard connections. It has a wide attenuation range, extremely low return loss, is polarization insensitive, and has excellent repeatability. With our highly integrated design and manufacturing capability, the attenuation of male-female type SC attenuator can also be customized to help our customers find better opportunities. Our attenuator complies with industry green initiatives,  such as ROHS.

    • OYI-FOSC-H20

      OYI-FOSC-H20

      The OYI-FOSC-H20 dome fiber optic splice closure is used in aerial, wall-mounting, and underground applications for the straight-through and branching splice of the fiber cable. Dome splicing closures are excellent protection of fiber optic joints from outdoor environments such as UV, water, and weather, with leak-proof sealing and IP68 protection.

    • GYFXTH-2/4G657A2

      GYFXTH-2/4G657A2

    • Armoured Patchcord

      Armoured Patchcord

      Oyi armoured patch cord provides flexible interconnection to active equipment, passive optical devices and cross connects. These patch cords are manufactured so as to withstand side pressure and repeated bending and are used in external applications in customer premises, central offices and in harsh environment. Armoured patch cords are constructed with a stainless steel tube over a standard patch cord with an outer jacket. The flexible metal tube limits the bending radius, preventing the optical fibre from breaking. This ensures a safe and durable optical fibre network system.

      According to the transmission medium, it divides to Single Mode and Multi Mode Fiber Optic Pigtail; According to the connector structure type, it divides FC, SC, ST, MU, MTRJ, D4, E2000, LC etc.; According to the polished ceramic end-face, it divides to PC, UPC and APC.

      Oyi can provide all kinds of optic fiber patchcord products; The transmission mode, optical cable type and connector type can be arbitrarily matched. It has the advantages of stable transmission, high reliability and customization; it is widely used in optical network scenarios such as central office, FTTX and LAN etc.

    If you're looking for a reliable, high-speed fibre optic cable solution, look no further than OYI. Contact us now to see how we can help you stay connected and take your business to the next level.

    Facebook

    YouTube

    YouTube

    Instagram

    Instagram

    LinkedIn

    LinkedIn

    Whatsapp

    +8618926041961

    Email

    sales@oyii.net