GJFJKH

Sab Hauv Tsev Armored Optic Cable

GJFJKH

Jacketed aluminium interlocking armor muab qhov pom kev sib npaug ntawm ruggedness, yoog raws thiab qhov hnyav. Multi-Strand Sab Hauv Tsev Armored Tight-Buffered 10 Gig Plenum M OM3 Fiber Optic Cable los ntawm luv nqi Tsawg Voltage yog ib qho kev xaiv zoo hauv cov tsev uas yuav tsum tau muaj zog los yog qhov chaw nas muaj teeb meem. Cov no kuj yog qhov zoo tagnrho rau kev tsim cov nroj tsuag thiab hnyav kev lag luam ib puag ncig nrog rau kev ua haujlwm siab ceev hauvcov chaw zov me nyuam. Interlocking armor tuaj yeem siv nrog lwm hom cable, suav nrogsab hauv/sab nraum zoovnruj-buffered cables.


Product Detail

FAQ

Khoom cim npe

Khoom nta

1. Kev ua haujlwm zoo thiab ua haujlwm kub.

2. Zoo heev crush kuj thiab yooj.

3. Hluav taws kub retardant sheath (LSH / PVC / TPEE) ua kom cov hluav taws kub ua haujlwm.

4. Haum rau kev siv sab hauv tsev.

STRUCTURE SPECIFICATION

Fiber suav

1

2

4

6

8

12

24

 

Tight Fiber

OD (mm):

0.9

0.6

Khoom siv:

PVC

Strength Member

Aramid xov paj

Sheath khoom

LSZH

 

Armored Kauv Tube

 

TIAB SA 304

OD ntawm Cable (mm) ± 0.1

3.0

3.0

5.0

5.0

5.0

6.0

6.0

Net nyhav (kg / km)

32

38

40

42

46

60

75

Max.Tensile Loading

(N)

500

500

500

500

500

500

500

Tight Buffer Xim Code

TSIS MUAJ.

1

2

3

4

5

6

Xim

Xiav

Txiv kab ntxwv

Ntsuab

Xim av

Slate

Dawb

TSIS MUAJ.

7

8

9

10

11

12

Xim

Liab

Dub

Daj

Violet

Paj yeeb

Aqua

OPTICAL FIBER

1. Tib hom Fiber

Yam khoom

UNITS

SPECIFICATION

Fiber hom

 

g652d ua

g657 ua

Attenuation

dB/km

1310nm≤ 0.4

1550nm≤ 0.3

 

Chromatic Dispersion

 

ps/nm.km

1310nm≤ 3.6

1550nm≤ 18

1625nm≤ 22

Zero Dispersion Slope

ps/nm2.km

≤ 0.092

Zero Dispersion Wavelength

nm

1300-1324 ib

Txiav tawm Wavelength (λcc)

nm

≤ 1260

Attenuation vs. dabtsi yog khoov (60mm x 100 tig)

dB

(30 hli radius, 100 rings) ≤ 0.1 @ 1625 nm

(10 hli radius, 1 nplhaib) ≤

1.5 @ 1625 nm

Hom Field Diameter

μm

9.2 ± 0.4 ntawm 1310 nm

9.2 ± 0.4 ntawm 1310 nm

Core-Clad Concentricity

μm

≤ 0.5

≤ 0.5

Cladding Txoj kab uas hla

μm

125 ± 1

125 ± 1

Cladding Non-circularity

%

≤ 0.8

≤ 0.8

Txheej Dia

μm

245 ± 5

245 ± 5

Pov thawj Test

Gpa

≥ 0.69

≥ 0.69

2.Ntau hom Fiber

Yam khoom

UNITS

SPECIFICATION

62.5/125

50/125

AWM 3-150

AWM 3-300

AWM 4-550

Fiber Core Diameter

ib m

62.5 ± 2.5

50.0 ± 2.5

50.0 ± 2.5

Fiber Core Non-circularity

%

≤ 6.0

≤ 6.0

≤ 6.0

Cladding Txoj kab uas hla

ib m

125.0 ± 1.0

125.0 ± 1.0

125.0 ± 1.0

Cladding Non-circularity

%

≤ 2.0

≤ 2.0

≤ 2.0

Txheej Dia

ib m

245 ± 10

245 ± 10

245 ± 10

Coat-Clad Concentricity

ib m

≤ 12.0

≤ 12.0

≤ 12.0

Txheej Tsis-circularity

%

≤ 8.0

≤ 8.0

≤ 8.0

Core-Clad Concentricity

ib m

≤ 1.5

≤ 1.5

≤ 1.5

Attenuation

850nm ua

dB/km

3.0

3.0

3.0

1 300nm

dB/km

1.5

1.5

1.5

 

 

OFL

850nm ua

MHz .km

≥160

≥ 200

≥700

≥1500

≥ 3500

1 300nm

MHz .km

≥300

≥400

≥ 500

≥ 500

≥ 500

Qhov loj tshaj txoj kev xav zauv aperture

 

0.275 ± 0.015

0.200 ± 0.015

0.200 ± 0.015

 

Mechanical thiab Environmental Performance ntawm Cable

TSIS MUAJ.

Yam khoom

TEST Txoj kev

ACCEPTANCE CRITERIA

 

 

 

1

 

 

 

Tensile Loading Test

#Test method: IEC 60794-1-E1 -. Ntev-tensile load: 0.5 npaug ntawm lub sij hawm luv luv rub quab yuam

-. Short-tensile load: siv rau kab lus 1.1

-. Cable ntev:50 m

 

-. Attenuation

increment@1550 nm: ≤ 0.4 dB - . Tsis muaj lub tsho tawg thiab fiber ntau

kev tawg

 

 

2

 

Crush Resistance Test

#Test method: IEC 60794-1-E3

-.Long-tensile load: 300 N / 100mm -.Short-tensile load: 1000 N / 100mm Load time: 1 feeb

 

 

-. Tsis muaj fiber ntau tawg

 

 

 

3

 

 

Impact Resistance Test

#Test method: IEC 60794-1-E4

-.Impact qhov siab: 1 m -.Impact hnyav: 100 g -.Ib tug taw tes: ≥3

-.Ib zaus: ≥ 1/point

 

 

 

-. Tsis muaj fiber ntau tawg

 

 

4

 

 

Rov qab khoov

#Test method: IEC 60794-1-E6

-.Mandrel txoj kab uas hla: 20 D -.Qhov hnyav: 2 kg

-.Bending zaus: 200 zaug -.Bending ceev: 2 s/time

 

 

-. Tsis muaj fiber ntau tawg

 

 

 

5

 

 

 

Torsion Test

#Test method: IEC 60794-1-E7

-.Length: 1 m

-.Qhov hnyav: 2 kg -.Angle: ± 180 degree -.Frequency: ≥ 10/point

 

 

 

-. Tsis muaj fiber ntau tawg

 

 

 

6

 

 

Kub Cycling Test

#Test method: IEC 60794-1-F1 -.Cub cov kauj ruam: + 20 ℃, - 10 ℃, + 60 ℃, + 20 ℃

-.Testing Sijhawm: 8 teev / kauj ruam -.Cycle index: 2

 

-. Attenuation

increment @ 1550 nm : ≤ 0.3 dB - . Tsis muaj lub tsho tawg thiab fiber ntau

kev tawg

 

7

 

Kub

Kev khiav hauj lwm: -10 ℃ ~ + 60 ℃

Khw / Thauj: -10 ℃ ~ + 60 ℃

Kev teeb tsa: -10 ℃ ~ + 60 ℃

FIBER OPTIC CABLE BENDING RADIUS

Static dabtsi yog khoov: ≥ 10 npaug tshaj cable tawm txoj kab uas hla

Dynamic dabtsi yog khoov: ≥ 20 zaug tshaj cable tawm txoj kab uas hla.

PACKAGE THIAB MARK

1. Pob
Tsis pub ob chav nyob ntev ntawm cable hauv ib lub nruas. Ob qhov kawg yuav tsum tau ntim rau hauv nruas, cia ntev ntawm cable tsis pub tsawg tshaj 1meter.
2. Mark
Cable Mark: Hom, Cable hom, Fiber hom thiab suav, Xyoo ntawm kev tsim khoom thiab Length marking.

dsgds ua

TEST REPORT

Daim ntawv tshaj tawm kev xeem thiab ntawv pov thawj yuav muab los ntawm kev thov.

Cov khoom pom zoo

  • OYI-FTB-10A Terminal Box

    OYI-FTB-10A Terminal Box

     

    Cov cuab yeej siv los ua qhov chaw txiav tawm rau lub feeder cable txuas nrogpoob kabhauv FTTx kev sib txuas lus network system. Cov fiber ntau splicing, splitting, faib yuav ua tau nyob rau hauv lub thawv no, thiab lub caij no nws muab kev tiv thaiv thiab kev tswj cov khoom.FTTx network building.

  • GYFXTH-2/4G657A2

    GYFXTH-2/4G657A2

  • OYI-FOSC-D108M

    OYI-FOSC-D108M

    OYI-FOSC-M8 dome fiber optic splice kaw yog siv rau hauv huab cua, phab ntsa-mounting, thiab hauv av daim ntaub ntawv rau kev ncaj-dhau thiab branching splice ntawm fiber ntau cable. Dome splicing kaw yog kev tiv thaiv zoo heev ntawm fiber ntau optic pob qij txha los ntawm qhov chaw sab nraum zoov xws li UV, dej, thiab huab cua, nrog rau cov ntaub ntawv pov thawj thiab IP68 tiv thaiv.

  • OYI-FAT H08C

    OYI-FAT H08C

    Lub thawv no yog siv los ua ib qho kev txiav tawm rau lub feeder cable los txuas nrog kev poob cable hauv FTTX kev sib txuas lus network system. Nws integrates fiber ntau splicing, splitting, faib, cia thiab cable txuas nyob rau hauv ib chav tsev. Lub caij no, nws muab kev tiv thaiv ruaj khov thiab kev tswj hwm rau lubFTTX network tsim.

  • OYI-F234-8Core

    OYI-F234-8Core

    Lub thawv no yog siv los ua qhov chaw txiav tawm rau lub feeder cable los txuas nrog kev poob cable hauvFTTX kev sib txuas lusnetwork system. Nws integrates fiber ntau splicing, splitting, faib, cia thiab cable txuas nyob rau hauv ib chav tsev. Meanwhile, nws muabkev tiv thaiv thiab kev tswj hwm rau FTTX network tsev.

  • OYI-FOSC-H06

    OYI-FOSC-H06

    OYI-FOSC-01H kab rov tav fiber ntau optic splice kaw muaj ob txoj kev sib txuas: kev sib txuas ncaj qha thiab kev sib cais. Lawv muaj feem xyuam rau cov xwm txheej xws li nyiaj siv ua haujlwm, txiv neej-qhov zoo ntawm cov kav dej, qhov teeb meem embedded, thiab lwm yam. Muab piv nrog lub thawv davhlau ya nyob twg, qhov kaw yuav tsum muaj kev sib khi ntau dua. Optical splice kaw yog siv los faib, splice, thiab khaws cov kab hluav taws xob sab nraum zoov uas nkag thiab tawm ntawm qhov kawg ntawm qhov kaw.

    Qhov kaw muaj 2 qhov chaw nkag. Lub plhaub ntawm cov khoom yog tsim los ntawm ABS + PP khoom. Cov kev kaw no muab kev tiv thaiv zoo rau cov fiber ntau optic pob qij txha los ntawm qhov chaw sab nraum zoov xws li UV, dej, thiab huab cua, nrog rau cov ntaub ntawv pov thawj thiab IP68 tiv thaiv.

Yog tias koj tab tom nrhiav kev txhim khu kev qha, kev kub ceev fiber ntau optic cable daws, saib tsis pub dhau OYI. Hu rau peb tam sim no kom pom tias peb tuaj yeem pab koj txuas nrog thiab coj koj txoj kev lag luam mus rau qib tom ntej.

Facebook

YouTube

YouTube

Instagram

Instagram

LinkedIn

LinkedIn

Whatsapp

+8618926041961

Email

sales@oyii.net