Can be installed without shutting off the power.
Resistant to high and low temperature cycles, resulting in anti-aging and a longer lifespan.
Lightweight and small diameter reduce the load caused by ice and wind, as well as the load on towers and backprops.
Large span lengths and the longest span is over 1000m.
Good performance in tensile strength and temperature.
Large number of fiber cores, lightweight, can be laid with the power line, saving resources.
Adopt high-tensile-strength aramid material to withstand strong tension and prevent wrinkles and punctures.
The design lifespan is over 30 years.
Fiber Type | Attenuation | 1310nm MFD
(Mode Field Diameter) |
Cable Cut-off Wavelength λcc(nm) | |
@1310nm(dB/KM) | @1550nm(dB/KM) | |||
G652D | ≤0.36 | ≤0.22 | 9.2±0.4 | ≤1260 |
G657A1 | ≤0.36 | ≤0.22 | 9.2±0.4 | ≤1260 |
G657A2 | ≤0.36 | ≤0.22 | 9.2±0.4 | ≤1260 |
G655 | ≤0.4 | ≤0.23 | (8.0-11)±0.7 | ≤1450 |
Fiber Count | Cable Diameter (mm) ±0.5 |
Cable Weight (kg/km) |
100m Span Tensile Strength (N) |
Crush Resistance (N/100mm) | Bending Radius (mm) |
|||
Long Term | Short Term | Long Term | Short Term | Static | Dynamic | |||
2-12 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
24 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
36 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
48 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
72 | 10 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
96 | 11.4 | 100 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
144 | 14.2 | 150 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
Power Line, dielectric needed or large span communication line.
Self-supporting aerial.
Temperature Range | ||
Transportation | Installation | Operation |
-40℃~+70℃ | -5℃~+45℃ | -40℃~+70℃ |
DL/T 788-2016
OYI cables are coiled on bakelite, wooden, or ironwood drums. During transportation, the right tools should be used to avoid damaging the package and to handle them with ease. Cables should be protected from moisture, kept away from high temperatures and fire sparks, protected from over-bending and crushing, and protected from mechanical stress and damage. It is not allowed to have two lengths of cable in one drum, and both ends should be sealed. The two ends should be packed inside the drum, and a reserve length of cable not less than 3 meters should be provided.
The color of cable markings is white. The printing shall be carried out at intervals of 1 meter on the outer sheath of the cable. The legend for the outer sheath marking can be changed according to the user's requests.
Test report and certification provided.